Symptoms

IANA recently assigned option code 0x0008 to the client-subnet option of the EDNS0 record. Previously, the value was undefined, but processed as 0x50fa by various vendors.

Impact

The BIG-IP software treats the newly assigned value, 0x0008, as malformed, and the query is dropped.

Conditions

EDNS0 with new client-subnet option code.

Workaround

None

Fix Information

Option code 0x0008 to the client-subnet of the EDNS0 record is now recognized, so the BIG-IP software now accepts both 0x50fa and 0x0008.