Bug ID 451446: Slot Status information and Sensor Tables not displayed

Last Modified: Aug 19, 2026

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.5.1, 11.5.1 hf1, 11.5.1 hf2, 11.5.1 hf3, 11.5.1 hf4, 11.5.1 hf5, 11.5.1 hf6, 11.5.1 hf7, 11.5.1 hf8, 11.5.1 hf9, 11.5.1 hf10, 11.5.1 hf11, 11.5.2, 11.5.2 hf1, 11.5.3, 11.5.3 hf1, 11.5.3 hf2, 11.5.4, 11.5.4 hf1, 11.5.4 hf2, 11.5.4 hf3, 11.5.4 hf4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10

Fixed In:
11.6.0

Opened: Mar 06, 2014

Severity: 3-Major

Related Article: K16099

Symptoms

1. Slot Status information is no longer displayed when you run a 'tmsh show sys hardware command' on the primary blade. 2. Sensor information tables are missing from tmctl and system_check reports.

Impact

No impact on normal operations. Just missing information.

Conditions

BIG-IP 2000-/4000-/5000-/7000-/10000-series appliances, VIPRION B2100/2150/2250 blades.

Workaround

Some missing sensor information is available through 'system_check -d' or 'tmsh show sys hardware' commands. Some missing slot status information is available through the 'bladectl -v' command.

Fix Information

Restored missing slot status and sensor tables.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips