Bug ID 451446: Slot Status information and Sensor Tables not displayed

Last Modified: Feb 13, 2019

Bug Tracker

Affected Product:  See more info
BIG-IP LTM(all modules)

Known Affected Versions:
11.4.1, 11.5.0, 11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4

Fixed In:
11.6.0, 11.5.1 HF5

Opened: Mar 06, 2014
Severity: 3-Major
Related AskF5 Article:
K16099

Symptoms

1. Slot Status information is no longer displayed when you run a 'tmsh show sys hardware command' on the primary blade. 2. Sensor information tables are missing from tmctl and system_check reports.

Impact

No impact on normal operations. Just missing information.

Conditions

BIG-IP 2000-/4000-/5000-/7000-/10000-series appliances, VIPRION B2100/2150/2250 blades.

Workaround

Some missing sensor information is available through 'system_check -d' or 'tmsh show sys hardware' commands. Some missing slot status information is available through the 'bladectl -v' command.

Fix Information

Restored missing slot status and sensor tables.

Behavior Change