Bug ID 453239: lsndb application can only be run on primary blade in chassis.

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP CGN(all modules)

Known Affected Versions:
11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10

Fixed In:
11.6.0

Opened: Mar 19, 2014

Severity: 3-Major

Related Article: K17429

Symptoms

Running the lsndb utility on a secondary blade with many connections might cause a hang in the display.

Impact

The lsndb utility is not supported on secondary blades. It is only supported on a primary blade.

Conditions

Running the lsndb utility on a secondary blade.

Workaround

Run the lsndb application on primary blade in the chassis.

Fix Information

Support is added to display an error message stating that this utility can only be run on the primary blade in the chassis.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips