Last Modified: Sep 13, 2023
Affected Product(s):
BIG-IP All
Known Affected Versions:
11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3
Opened: Jun 19, 2014 Severity: 3-Major
On BIG-IP 2000, 4000, 5000, 7000, 10000 series platforms platforms configured for high availability (HA) connected via the HA failover cable, if the active unit is powered off; the newly active unit interprets the status from the powered-down unit as 'active'.
This causes the command 'show cm traffic-group' to erroneously show the status of the powered-down unit as 'active'. In some instances, the newly active unit forces itself to 'Standby' to clear the 'active-active' state. The faulty indication is intermittent and not related to licensing or software version.
This occurs when powering down BIG-IP 2000, 4000, 5000, 7000, 10000 series platform HA configurations connected by HA failover cables with device-group/group-type set to sync-failover.
Remove cable from powered-down peer.
None