Bug ID 471492: IP reputation on small VCMP instances and older platforms

Last Modified: Sep 06, 2019

Bug Tracker

Affected Product:  See more info
BIG-IP All(all modules)

Known Affected Versions:
11.2.1, 11.4.0, 11.4.1, 11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 14.0.0, 14.0.0.1, 14.0.0.2, 14.0.0.3, 14.0.0.4, 14.0.0.5, 14.0.1, 14.1.0, 14.1.0.1, 14.1.0.2, 14.1.0.3, 14.1.0.4, 14.1.0.5, 14.1.0.6, 14.1.2

Opened: Jul 11, 2014
Severity: 4-Minor

Symptoms

When running IP reputation database on small (less than or equal to 4 GB) vCMP or VE instances, or on older platforms with less than or equal to 4 GB of memory, iprepd can use enough memory to make the system wait for disk I/O. This can make the system sluggish when disk operations are taking place.

Impact

Extensive disk I/O, such as logging to disk or rotating logs, or when installing software, might result in a system that does not respond to user interaction as expected. Swap might increase, as well.

Conditions

This typically exists on HDD equipped systems only. SSD systems are typically not affected.

Workaround

Provision 'large control plane' in the GUI provisioning page. Alternatively, add 100 to the existing value of the db variable provision.extramb. (which is zero by default).

Fix Information

None

Behavior Change