Last Modified: Nov 07, 2022
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3
Fixed In:
12.0.0, 11.6.0 HF4, 11.5.1 HF5, 11.4.1 HF6
Opened: Aug 01, 2014 Severity: 3-Major Related Article:
K15840
An sFlow error may occur during config sync or load of a BIG-IP device.
Config sync or load operation might fail. This occurs rarely. When this occurs, the system posts a message similar to the following: 'Can't save/checkpoint DB object, class:sflow_http_virtual_data_source status:13'
Exact conditions are unknown and difficult to reproduce, but some possible conditions include config sync or load operations following delete/create of a virtual server or profiles (either directly or by deleting/creating an iApp), sync following failover,
Force the mcpd process to reload the BIG-IP configuration. For more information, see K13030, Forcing the mcpd process to reload the BIG-IP configuration, available here: Link: https://support.f5.com/csp/article/K13030.
The ConfigSync operation completes successfully, and the sFlow error no longer occurs.