Bug ID 474613: Upgrading from previous versions

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP AVR, Install/Upgrade(all modules)

Known Affected Versions:
11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.5.3 HF1, 11.5.3 HF2, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.2.1, 11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.1.0 HF1, 12.1.0 HF2, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2

Fixed In:
12.0.0, 11.6.1 HF2, 11.5.4

Opened: Aug 06, 2014

Severity: 3-Major

Related Article: K58231070

Symptoms

Configuration upgrade from versions 11.2, 11.1, or 11.0 fails when two analytics profiles on different partitions are configured with the same remote login server IP address.

Impact

Upgrade process fails.

Conditions

Upgrading from versions 11.2, 11.1, or 11.0 when two analytics profiles on different partitions are configured with the same remote login server IP address.

Workaround

Remove the external logging configuration on the source partition, upgrade, and then restore the configuration as needed.

Fix Information

Configuration upgrade from versions 11.2, 11.1, or 11.0 now succeeds and works correctly even when two analytics profiles on different partitions are configured with the same remote login server IP address.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips