Bug ID 477700: Detail missing from power supply 'Bad' status log messages

Last Modified: Oct 17, 2023

Affected Product(s):
BIG-IP All(all modules)

Known Affected Versions:
11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.5.3 HF1, 11.5.3 HF2, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.2.1, 11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3

Fixed In:
11.6.1 HF2, 11.5.7

Opened: Sep 03, 2014

Severity: 4-Minor

Related Article: K04116117

Symptoms

When an internal hardware sensor alert is received indicating a 'Bad' power supply status, no detail is included which indicates which characteristic of the power supply's state is resulting in a 'Bad' overall status for the power supply. In this scenario, the message logged at default logging level contains information similar to the following: ... crit chmand[...]: 012a0013:2: Blade 0 hardware sensor critical alarm: Power Supply 2 GPIO status(SPAFFIV03G): Bad

Impact

Unable to diagnose cause of 'Bad' power supply status at default logging level to determine whether the probable cause is due to a power supply hardware fault or a possible external power source issue.

Conditions

BIG-IP 2000-/4000-/5000-/7000-/10000-series appliances or VIPRION B2100-/B2200-series blades, in which one or more installed power supplies triggers an internal hardware sensor alert indicating a 'Bad' power supply status.

Workaround

If power supply errors continue to be logged: 1. Set the libhal logging level to 'Debug': tmsh mod sys db log.libhal.level { value "Debug" } 2. Let the system run in this configuration for at least a few minutes to collect a number of chmand error logs, such as: ... debug chmand[...]: 012a0007:7: Power Supply 1 alert objid:0x16f local:1 status:0x3 pin:0x2 action:0xd ... debug chmand[...]: 012a0007:7: Received Sensor Alert: sensor id 0x16f slot 0xff ... debug chmand[...]: 012a0007:7: Power Supply 1 alert objid:0x16f local:1 status:0x1 pin:0x2 action:0x3. 3. Set the libhal logging level back to 'Notice': tmsh mod sys db log.libhal.level { value "Notice" } 4. Take a qkview or an archive of /var/log/ltm, and engage F5 Professional Services for further analysis.

Fix Information

When an internal hardware sensor alert is received indicating a 'Bad' power supply status, additional detail is now logged to help identify the cause of the 'Bad' overall status for the power supply.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips