Bug ID 479084: ZoneRunner can fail to respond to commands after a VE resume.

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP GTM, Link Controller(all modules)

Known Affected Versions:
11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.5.3 HF1, 11.4.1, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.1.0 HF1, 12.1.0 HF2, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2

Fixed In:
12.0.0, 11.6.0 HF6, 11.5.3 HF2, 11.4.1 HF9

Opened: Sep 12, 2014

Severity: 4-Minor

Symptoms

The ZoneRunner GUI can become unresponsive after a VE resume.

Impact

ZoneRunner cannot create/modify/delete/query records from the on box BIND server

Conditions

This is due to the "lo:" interface not being recreated during the resume processing. ZoneRunner relies on this interface to communicate with the on box BIND server.

Workaround

Restart ZoneRunner after a VE resume with the command: bigstart restart zonerunner.

Fix Information

ZoneRunner now uses the tmm0 interface to communicate with BIND.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips