Last Modified: Nov 07, 2022
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
11.2.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3
Fixed In:
11.6.0 HF4, 11.5.1 HF5, 11.4.1 HF6
Opened: Sep 15, 2014 Severity: 3-Major Related Article:
K16641
Error message in ltm log: bcm56xxd: reading L2 entry Operation failed bs_arl.cpp.
Error messages in /var/log/ltm. Messages appear similar to the following: err bcm56xxd[7453]: 012c0011:3: Error: reading L2 entry 68416: Operation failed bs_arl.cpp(1579)
bcm56xxd periodically reads the switch's internal L2 table to save certain L2 information for internal debug use. Reads to unused entries of this table might fail and produce an error.
None.
In this release, the seldom-used internal debug table has been removed, which eliminates the periodic accesses.