Last Modified: Jul 12, 2023
Affected Product(s):
BIG-IP All
Known Affected Versions:
11.6.0
Fixed In:
12.0.0, 11.6.1
Opened: Sep 19, 2014 Severity: 3-Major Related Article:
K17080
The system posts messages in ltm log similar to the following: err mcpd[7172]: 0107167d:3: Data publisher not found or not implemented when processing request (unknown request), tag (20594).
For bladed systems, the system does not report the blade voltage. For systems that are not bladed system, there is no publisher for this query. This message is cosmetic for non-bladed systems, and you can safely ignore it.
This occurs on a bladed system from an snmp query against blade_voltage_stat.
None.
The main query processing file was not included during build-time. The file has been added and the stats should now show as expected.