Bug ID 480272: During OAM SDK initialization, ObConfig initialization returns wrong accessgate ID

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP APM(all modules)

Known Affected Versions:
11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.5.3 HF1, 11.5.3 HF2, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.1.0 HF1, 12.1.0 HF2, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2

Fixed In:
12.0.0, 11.6.0 HF6, 11.5.4, 11.4.1 HF9

Opened: Sep 19, 2014

Severity: 2-Critical

Related Article: K17117

Symptoms

OAM ObConfig Initialization returns wrong accessgate ID, and that resulted in EAM setting wrong domain for the ObSSOCookie.

Impact

The impact of this issue is that ObConfig initialization returns the wrong accessgate ID.

Conditions

After network connection failure with backend OAM server, ObConfig initilization returned past Accessgate ID.

Workaround

This issue has no workaround at this time.

Fix Information

AccessGate init should now fail initialization and retry in case of an AccessGate ID mismatch. If all retries fail, then the AccessGate remains uninitialized. The administrator should clear the config cache for all the AccessGates and restart the EAM process.

Behavior Change

Guides & references