Bug ID 480679: The big3d daemon does not receive config updates from mcpd

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.5.3 HF1, 11.5.3 HF2, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 12.1.0 HF1, 12.1.0 HF2, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2

Fixed In:
12.0.0, 11.6.0 HF6

Opened: Sep 23, 2014

Severity: 3-Major

Related Article: K16858

Symptoms

Any Enterprise Manager device connected to a BIG-IP v11.6.0 will not receive configuration change notifications (including status) for nodes, pool members, or pools and will require manual refresh of configuration for those types. Stats and other configuration items remain unaffected.

Impact

The impact of this bug is that Enterprise Manager devices will not receive configuration update notifications for nodes, pool members, or pools. This includes status changes. Stats and other configuration items remain unaffected.

Conditions

This only affects EM devices and potentially MangementPack connections to a BIG-IP. The BIG-IP must be version 11.6.0 only, but the EM may be any version.

Workaround

This issue has no workaround at this time.

Fix Information

The mapping for subscription groups has been fixed so that the SUBSCRIPTION_NODE_ADDRESS and other similar subscription groups will not be overwritten by the SUBSCRIPTION_MONITOR group.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips