Last Modified: Nov 22, 2021
Affected Product(s):
BIG-IP All
Known Affected Versions:
11.4.1
Fixed In:
11.4.1 HF9
Opened: Nov 18, 2014 Severity: 3-Major Related Article:
K17093
The HiGig MAC (HGM) registers are not dumped to the log files when an HSB transmitter failure occurs.
Only part of the log registered are dumped to the log files when an HSB transmitter failure occurs. The following HiGig event and HSB transmitter failure are present in the log files: -- info bcm56xxd[7746]: 012c0015:6: Link: 4.3 is DOWN -- info bcm56xxd[7746]: 012c0012:6: Reset HSBe2 (bus 1) HGM2 MAC completed on higig2 link 4.3 down event. -- info bcm56xxd[7746]: 012c0015:6: Link: 4.3 is UP -- crit tmm5[14718]: 01230111:2: Interface 0.6: HSB DMA lockup on transmitter failure.
When an HSB transmitter failure occurs due to an issue in the HiGig MAC, there is not enough information in the log files to determine the cause of the lockup.
None
HiGig MAC registers are now correctly dumped to log file on HSB transmitter failure.