Last Modified: Jul 13, 2024
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6
Fixed In:
13.0.0
Opened: Dec 02, 2014 Severity: 4-Minor
System matches to previous Diameter Route Application ID after modifying the application ID value.
The Diameter Route might continue to match Diameter messages against the old application ID until TMM is restarted.
This occurs after modifying the application ID value for a Diameter Route object.
Always restart TMM after changing the value of application ID in a Diameter Route.
System now matches to the correct Diameter Route Application ID after modifying the application ID value.