Bug ID 501612: Spurious Configuration Synchronizations

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP ASM(all modules)

Known Affected Versions:
11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.5.3 HF1, 11.5.3 HF2, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.2.1, 11.4.1, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.1.0 HF1, 12.1.0 HF2, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2

Fixed In:
12.0.0, 11.6.0 HF5, 11.5.3

Opened: Jan 19, 2015

Severity: 3-Major

Symptoms

Some items (for example, Incidents) were considered to be config elements that require synchronization when their status changes (such as being read), but are not actually synchronized in a device group.

Impact

The synchronization state of a device group erroneously changes to "Pending"

Conditions

Event Correlation Incidents occur and are read by the user while in a manual sync device group for ASM.

Workaround

None.

Fix Information

Items that are not synchronized across a device group no longer cause changes to the synchronization state.

Behavior Change

Guides & references