Last Modified: Nov 07, 2022
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8
Fixed In:
12.0.0, 11.6.1
Opened: Feb 03, 2015 Severity: 3-Major Related Article:
K17419
When an FQDN Node has no Node Default or Node Specific monitor associated, the ephemeral nodes' status is 'Unknown (enabled)- Node address service checking is enabled but result is not available yet.' A standard node configured without a monitor has the correct status: 'Unknown (enabled) - Node address does not have service checking enabled.'
Cannot determine actual state of pool member.
FQDN node created with one or more valid records returned for the FQDN, and no node default or node-specific health monitor configured.
None.
FQDN node without service checking has the correct status: 'Unknown (enabled) - Node address does not have service checking enabled.'