Bug ID 507782: TMM crashes for Citrix connection when Address field in the ICA file has non-patched/invalid data

Last Modified: Oct 25, 2026

Affected Product(s):
BIG-IP APM(all modules)

Known Affected Versions:
11.5.1, 11.5.1 hf1, 11.5.1 hf2, 11.5.1 hf3, 11.5.1 hf4, 11.5.1 hf5, 11.5.1 hf6, 11.5.1 hf7, 11.5.1 hf8, 11.5.1 hf9, 11.5.1 hf10, 11.5.1 hf11, 11.5.2, 11.5.2 hf1, 11.6.0, 11.6.0 hf1, 11.6.0 hf2, 11.6.0 hf3, 11.6.0 hf4, 11.6.0 hf5, 11.6.0 hf6, 11.6.0 hf7, 11.6.0 hf8, 11.6.1, 11.6.1 hf1, 11.6.1 hf2, 11.6.2, 11.6.2 hf1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3

Fixed In:
12.0.0, 11.5.3

Opened: Feb 18, 2015

Severity: 2-Critical

Symptoms

TMM crashes on an attempt to open Citrix connection

Impact

Traffic disrupted while tmm restarts.

Conditions

Unpatched/malformed ICA file received by the client

Workaround

None

Fix Information

Fixed validation for the input data sent in the ICA connection so that for the invalid/non-patched Address it will reject the connection instead of crashing.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips