Bug ID 510709: Websso start URI match fails if there are more than 2 start URI's in SSO configuration.

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP APM(all modules)

Known Affected Versions:
11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.5.3 HF1, 11.4.1, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.1.0 HF1, 12.1.0 HF2, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2

Fixed In:
12.0.0, 11.6.0 HF6, 11.5.3 HF2, 11.4.1 HF9

Opened: Mar 05, 2015

Severity: 3-Major

Symptoms

If more than 2 start URIs are configured, start URI parsing does not work correctly. This results in no start URI match and websso failure.

Impact

SSO V1(websso) fails for configured start URI due to start URI mismatch.

Conditions

SSO error happens only if there are more than 2 start URIs configured in the SSO configuration.

Workaround

No workaround

Fix Information

Websso config start URI parsing was wrong when there are multiple lines in start URI configuration. Websso start URI parsing is fixed.

Behavior Change

Guides & references