Bug ID 510888: [LC] snmp_link monitor is not listed as available when creating link objects

Last Modified: Jul 18, 2026

Affected Product(s):
BIG-IP GTM, LTM(all modules)

Known Affected Versions:
11.5.1, 11.5.1 hf1, 11.5.1 hf2, 11.5.1 hf3, 11.5.1 hf4, 11.5.1 hf5, 11.5.1 hf6, 11.5.1 hf7, 11.5.1 hf8, 11.5.1 hf9, 11.5.1 hf10, 11.5.1 hf11, 11.5.2, 11.5.2 hf1, 11.5.3, 11.5.3 hf1, 11.5.3 hf2, 11.6.0, 11.6.0 hf1, 11.6.0 hf2, 11.6.0 hf3, 11.6.0 hf4, 11.6.0 hf5, 11.6.0 hf6, 11.6.0 hf7, 11.6.0 hf8, 11.6.1, 11.6.1 hf1, 11.6.1 hf2, 11.6.2, 11.6.2 hf1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3

Fixed In:
12.0.0, 11.5.4

Opened: Mar 06, 2015

Severity: 3-Major

Related Article: K16567

Symptoms

GUI: snmp_link is not listed from Available monitor list when creating link objects. TMSH: snmp_link is not shown when using TAB to show monitor options when creating link objects.

Impact

Cannot determine whether snmp_link monitor can be used. Must manually input snmp_link to associate snmp_link to a link object.

Conditions

When creating GTM link objects.

Workaround

Through tmsh, manually type snmp_link as monitor when creating link objects.

Fix Information

snmp_link monitor is now listed as available when creating link objects.

Behavior Change

Guides & references