Bug ID 513706: Incorrect metric restoration on Network Access on disconnect (Windows)

Last Modified: Oct 07, 2023

Affected Product(s):
BIG-IP APM(all modules)

Known Affected Versions:
11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.5.3 HF1, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.1.0 HF1, 12.1.0 HF2, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2

Fixed In:
12.1.0, 12.0.0, 11.6.0 HF6, 11.5.3 HF2

Opened: Mar 21, 2015

Severity: 3-Major

Related Article: K16958

Symptoms

The metric after Network Access disconnect differs from metric before Network Access for default route.

Impact

A multi-home environment might experience routing issues after disconnecting Network Access, for example, by default traffic might go through Wi-Fi instead of wired networks.

Conditions

Using Network Access on Windows systems.

Workaround

Disable and enable the network adapter.

Fix Information

Fixed an issue causing incorrect metric restoration on Network Access on disconnect.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips