Last Modified: Apr 28, 2025
Affected Product(s):
BIG-IP APM
Known Affected Versions:
11.5.1, 11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5
Fixed In:
12.0.0, 11.6.0 HF6, 11.5.3 HF2
Opened: Apr 20, 2015 Severity: 3-Major
The class attribute should be sent back to RADIUS server unmodified. However, if the RADIUS server is configured to send lots of long class attributes, the BIG-IP system might drop them when sending accounting stop message.
RADIUS Accounting server doesn't receive STOP message when user session is over.
The BIG-IP system is configured with an Access Policy that contains RADIUS Acct agent. The RADIUS server is configured to send class attributes with total size of greater than 512bytes.
None
Previously, the BIG-IP system would not send an accounting stop message if class attributes were more than 512 bytes total size. Now, BIG-IP system sends the accounting stop message, but does not include class attributes.