Last Modified: Sep 13, 2023
Affected Product(s):
BIG-IP GTM
Known Affected Versions:
10.0.0, 10.1.0, 10.2.4, 11.0.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.5.3 HF1, 11.1.0, 11.2.0, 11.3.0, 11.4.0, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.1.0 HF1, 12.1.0 HF2, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2
Fixed In:
12.0.0, 11.6.0 HF6, 11.5.3 HF2
Opened: Apr 29, 2015 Severity: 3-Major Related Article:
K31002924
Using the string returned in the options_seq field by the iControl Management.Zone.get_zone method in the Management.Zone.set_zone_option method can result in an 'Invalid zone option syntax...' error.
Strings returned in the options_seq field by the iControl Management.Zone.get_zone method cannot be used in the Management.Zone.set_zone_option() method unless they are reformatted consistent with the format expected by the Management.Zone.set_zone_option() method.
Use of the string returned by the iControl Management.Zone.get_zone method in the Management.Zone.set_zone_option() method.
Use the GUI to set the zone options. Alternatively, modify the strings returned in the options_seq field by the iControl Management.Zone.get_zone method to a format consistent with those expected by the Management.Zone.set_zone_option() method. For example, modify options_seq to have each option as a single string (rather than the masters string, which is returned as 3 separate options strings).
The iControl Management.Zone.get_zone_v2() method returns a value in the options_seq field in a format that is consistent with the format expected by the Management.Zone.set_zone_option() method.