Last Modified: Sep 13, 2023
Affected Product(s):
BIG-IP All
Known Affected Versions:
11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.6.0, 12.0.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2
Fixed In:
12.1.0, 12.0.0 HF1, 11.6.1, 11.5.4
Opened: Jun 08, 2015 Severity: 2-Critical
Intermittent lost connections to virtual servers or pool nodes with no observable errors on external interfaces. Errors are observed on internal interfaces using 'tmos show net interface -hidden'
Lost connections
Normal operation. This can occur on BIG-IP 8950, 11000, and 11050 platforms.
None.
An issue with intermittent lost connections with no errors on the external interface has been corrected.