Bug ID 528295: Virtual ARP ICMP echo settings are flipped on reloading a 10.x configuration on 11.4.x or later.

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1

Opened: Jun 16, 2015

Severity: 3-Major

Related Article: K40735404

Symptoms

A 10.x UCS containing LTM virtual servers with ARP set to disable. Loading the 10.x UCS on 11.4.x or later system leads to the ARP and ICMP echo setting value being flipped each time the load occurs.

Impact

ARP and ICMP echo setting value being flipped each time the load occurs. Note that the ICMP echo virtual field will be flipped even if ARP is enabled.

Conditions

Reloading a 10.x UCS containing virtual servers on 11.4.x or later system.

Workaround

Delete the LTM virtual servers on the 11.x/12.x version system prior to re-loading the 10.x UCS.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips