Bug ID 530530: tmsh sys log filter is displayed in UTC time

Last Modified: Apr 28, 2025

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
11.4.1, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1

Fixed In:
13.1.0, 12.1.3, 11.6.3.3, 11.5.7

Opened: Jun 29, 2015

Severity: 3-Major

Related Article: K07298903

Symptoms

When using the time-based log filters hour, minute, and second, tmsh returns results based on UTC time.

Impact

tmsh does not filter the log correctly with 'range' filter.

Conditions

Use range filter for 'tmsh show sys log' in either of the following ways: Filter logs by hour. Filter logs for less than 8 hours.

Workaround

Calculate the difference between the local BIG-IP system time and UTC, or change the system time to UTC.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips