Bug ID 533889: Counter64 support in custom_mibs

Last Modified: Apr 10, 2019

Bug Tracker

Affected Product:  See more info
BIG-IP TMOS(all modules)

Fixed In:
12.1.0

Opened: Jul 16, 2015
Severity: 3-Major

Symptoms

Counter64 was not support for snmpV2c queries using the custom_mib definitions.

Impact

Customers that would like to define a counter64 mib variable using the custom_mib.tcl file, could not.

Conditions

If a counter64 mib variable was defined in the custom_mib.tcl file, the snmp query would return a counter32.

Workaround

No workaround

Fix Information

Counter64 syntax is now supported in custom_mibs. The support is for snmpV2c queries only.

Behavior Change