Last Modified: Nov 07, 2022
Affected Product:
See more info
BIG-IP All
Known Affected Versions:
11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.10, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 12.0.0
Fixed In:
12.1.0, 12.0.0 HF1, 11.6.1 HF1, 11.5.4
Opened: Aug 06, 2015
Severity: 3-Major
Related Article:
K72329124
A list of sensors is displayed in the sensor_limit_table or by the system_check utility, with the actions taken when the sensor data exceeds its defined limit. On the affected versions, each sensor item is displayed only once, even if multiple limits and actions are defined for the sensor. Additional limits and actions defined for the sensor are not displayed.
The system does not show the complete set of defined sensor limits and corresponding BIG-IP system actions when there are multiple limits and actions defined. Only one action is displayed for each sensor. The system_check utility will only evaluate sensor measurements against limits that appear in its sensor limit tables. Missing sensor limits will not be evaluated, and corresponding alerts will not be issued.
This problem occurs when the affected version of the BIG-IP software is running on the following hardware platforms: BIG-IP 2000-/4000-/5000-/7000-/10000-/12000-series appliances and VIPRION B2100, B2150, B2250 blades.
None.
The system now shows a list of sensors in the sensor_limit_table or by the system_check utility, with the actions taken when the sensor data exceeds its defined limit.