Last Modified: Sep 13, 2023
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
11.0.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.5.1 HF1, 11.6.1 HF1, 11.5.1 HF2, 11.6.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2 HF1, 11.6.2 HF1, 11.5.3 HF1, 11.5.3 HF2, 11.5.4 HF1, 11.1.0, 11.2.0, 11.2.1, 11.3.0, 11.4.0, 11.4.1, 11.6.0, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2
Fixed In:
12.1.0, 11.6.1, 11.5.4 HF2
Opened: Aug 20, 2015 Severity: 3-Major Related Article:
K55193012
Monitors that have a send, recv, or recv-disable attribute set to 'none' are lost on configuration save.
Monitor may send unexpected string.
Monitor has a send, recv, or recv-disable attribute set to 'none'.
None.
Monitor send, recv, and recv-disable attributes now retains a 'none' value on configuration save.