Bug ID 541693: Monitor inheriting time-until-up and up-interval from parent incorrectly via GU

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2

Fixed In:
12.1.0

Opened: Aug 25, 2015

Severity: 4-Minor

Related Article: K32391836

Symptoms

Monitors inherit incorrect time-until-up and up-interval from parent.

Impact

The child monitor's time-until-up interval value is set to default (0). The up-interval value is incorrectly inherited from the parent.

Conditions

Create a parent monitor with non-default time-until-up and up-interval values. Using the GUI, create a child monitor.

Workaround

Set the time-until-up value for the child to the desired value.

Fix Information

A child monitor now inherits time-until-up and up-interval settings from the parent monitor.

Behavior Change