Bug ID 553446: Interface bfd session does not appear in configuration file or in show running-config

Last Modified: Apr 10, 2019

Bug Tracker

Affected Product:  See more info
BIG-IP All(all modules)

Known Affected Versions:
11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4

Fixed In:
12.1.0

Opened: Oct 20, 2015
Severity: 3-Major
Related AskF5 Article:
K44842083

Symptoms

When a Bi-Directional Forwarding Detection (BFD) session is configured for an interface, the bfd session command does not appear in the show running config or in the configuration file. However, running show bfd session command shows that a session is configured.

Impact

Cannot determine whether a bfd session is configured. Further, because it is not save in the configuration file, the bfd session configuration is lost when the system restarts the protocol.

Conditions

Interface bfd session between two nodes.

Workaround

None.

Fix Information

The configured interface bfd session is saved in the configuration file and shows up in the show running configuration.

Behavior Change