Bug ID 561444: LCD might display incorrect output.

Last Modified: Apr 10, 2019

Bug Tracker

Affected Product:  See more info
BIG-IP All(all modules)

Known Affected Versions:
10.2.1, 10.2.2, 10.2.3, 10.2.4, 11.0.0, 11.1.0, 11.2.0, 11.2.1, 11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1

Fixed In:
13.0.0, 12.1.1 HF2, 11.5.9

Opened: Dec 04, 2015
Severity: 3-Major
Related AskF5 Article:
K33435615

Symptoms

Incorrect LCD display due to garbled messages received from LCD panel.

Impact

LCD may display incorrect data.

Conditions

This occurs in various situations. Multiple messages sent to LCD and user interaction on LCD seem to reproduce the issue.

Workaround

The LCD usually corrects itself eventually, but to restore it immediately to a good state, run the following command: bigstart restart fpdd.

Fix Information

The issue allowing garbled messages between the front panel display daemon (fpdd) and the LCD daemon (LCDd) is now prevented from happening.

Behavior Change