10.2.1, 10.2.2, 10.2.3, 10.2.4, 11.0.0, 11.1.0, 11.2.0, 11.2.1, 11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.10, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1
Fixed In:
13.0.0, 12.1.1 HF2, 11.6.5.1, 11.5.9
Opened: Dec 04, 2015 Severity: 3-Major Related Article:
K33435615
Incorrect LCD display due to garbled messages received from LCD panel.
LCD may display incorrect data.
This occurs in various situations. Multiple messages sent to LCD and user interaction on LCD seem to reproduce the issue.
The LCD usually corrects itself eventually, but to restore it immediately to a good state, run the following command: bigstart restart fpdd.
The issue allowing garbled messages between the front panel display daemon (fpdd) and the LCD daemon (LCDd) is now prevented from happening.