Last Modified: Sep 13, 2023
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1
Fixed In:
12.1.2 HF1
Opened: Dec 09, 2015 Severity: 3-Major Related Article:
K81237532
FQDN nodes do not support monitor alias destinations.
The BIG-IP system does not send health checks to the configured monitor alias port. Monitor doesn't work as expected.
Configure a monitor with an alias address or port. The system will either prevent you from configuring, or the monitor will only be directed to the node address or port.
Depending on the functionality needed, you might be able to work around this by using an alternative configuration.
FQDN nodes now support monitor alias destinations.