Bug ID 566342: Cannot set 10T-FD or 10T-HD on management port

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Known Affected Versions:
12.1.0, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5, 13.1.3, 13.1.3.1, 13.1.3.2, 13.1.3.3, 13.1.3.4, 13.1.3.5, 13.1.3.6, 13.1.4, 13.1.4.1, 13.1.5, 13.1.5.1

Fixed In:
12.1.1

Opened: Jan 07, 2016

Severity: 3-Major

Symptoms

When setting the B4450 or B4300 mgmt port to 10T-FD or 10T-HD, there is no link LED. However, the peer unit shows the correct link LED for this setting.

Impact

Unable to set this media type.

Conditions

B4450 or B4300 blade and you want to set 10T-FD or 10T-HD media type

Workaround

None

Fix Information

The management port of B4450 and B4300 blades can now be configured with 10T-FD or 10T-HD

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips