Bug ID 570855: DB variable log.csyncd.level cannot be set to certain values

Last Modified: Apr 28, 2025

Affected Product(s):
BIG-IP All(all modules)

Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0

Fixed In:
13.1.0, 13.0.0 HF1

Opened: Jan 29, 2016

Severity: 4-Minor

Symptoms

The DB variable log.csyncd.level lists some values for tab completion, but validation prevents you from setting them. The error message looks like this: 01070911:3: The requested enumerated (alert) is invalid (critical, error, warning, notice, informational, debug) for loglevel in daemon_csyncd (/Common/daemon_csyncd)

Impact

You cannot set the log level to certain values.

Conditions

You are trying to use the DB variable log.csyncd.level to increase the amount of information logged by csyncd. csyncd is a system service that on chassis mirrors certain portions of the filesystem between blades, and on all BIG-IP devices runs certain commands after detecting filesystem changes.

Workaround

If you want more debugging information, set the log level to 'debug', which is still accepted.

Fix Information

The DB variable log.csyncd.level lists some values for tab completion, but validation formerly prevented you from setting them. This has now been resolved; all advertised values will now be accepted.

Behavior Change

Guides & references