Last Modified: Apr 28, 2025
Affected Product(s):
BIG-IP All
Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6, 13.0.0
Fixed In:
13.1.0, 13.0.0 HF1
Opened: Jan 29, 2016 Severity: 4-Minor
The DB variable log.csyncd.level lists some values for tab completion, but validation prevents you from setting them. The error message looks like this: 01070911:3: The requested enumerated (alert) is invalid (critical, error, warning, notice, informational, debug) for loglevel in daemon_csyncd (/Common/daemon_csyncd)
You cannot set the log level to certain values.
You are trying to use the DB variable log.csyncd.level to increase the amount of information logged by csyncd. csyncd is a system service that on chassis mirrors certain portions of the filesystem between blades, and on all BIG-IP devices runs certain commands after detecting filesystem changes.
If you want more debugging information, set the log level to 'debug', which is still accepted.
The DB variable log.csyncd.level lists some values for tab completion, but validation formerly prevented you from setting them. This has now been resolved; all advertised values will now be accepted.