Bug ID 573584: CPLD update success logs at the same error level as an update failure

Last Modified: May 01, 2019

Bug Tracker

Affected Product:  See more info
BIG-IP TMOS(all modules)

Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1, 13.1.0, 13.1.0.1, 13.1.0.2, 13.1.0.3, 13.1.0.4, 13.1.0.5, 13.1.0.6, 13.1.0.7, 13.1.0.8, 13.1.1, 13.1.1.1, 13.1.1.2, 13.1.1.3, 13.1.1.4, 13.1.1.5

Fixed In:
12.1.1

Opened: Feb 12, 2016
Severity: 3-Major

Symptoms

On booting after a successful CPLD update, you see an error in /var/log/ltm: "err chmand[4933]: 012a0003:3: CPLD not updated after previous power cycle."

Impact

The message is logged as an error, but it actually means that the CPLD version is as it is expected to be. This error can be safely ignored.

Conditions

This occurs during reboot after a successful firmware update

Workaround

None

Fix Information

CPLD update not required is now logged at the info level, not error.

Behavior Change