Bug ID 578413: Missing reference to customization-group from connectivity profile if created via portal access wizard

Last Modified: Oct 16, 2023

Affected Product(s):
BIG-IP APM(all modules)

Known Affected Versions:
11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 12.1.2, 12.1.3, 12.1.3.1

Fixed In:
13.0.0, 12.1.3.2

Opened: Mar 07, 2016

Severity: 3-Major

Symptoms

An extra customization group is created for connectivity profile when the profile is created via portal access wizard and the configuration is reloaded.

Impact

There is no functional impact since customization is not actually used for connectivity group.

Conditions

Use portal access wizard to create configure objects.

Workaround

Create configure object manually rather than via wizard.

Fix Information

There will be a reference to customization group from connectivity profile when the profile is created by wizard.

Behavior Change

Guides & references