Bug ID 586550: No preconditioning provided

Last Modified: Mar 02, 2023

Bug Tracker

Affected Product:  See more info
BIG-IP LTM(all modules)

Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2

Fixed In:
12.1.1

Opened: Apr 11, 2016
Severity: 3-Major

Symptoms

bcm56xxd provides tuning (also known as precondtioning) for 100G modules. bcm56xxd will issue log messages of the form: bs_module_do_precond :No preconditioning provided for module on port X.x.

Impact

None. This message is informational only and is indicating that a module was found for which no tuning is required.

Conditions

This message will be observed when optics modules are discovered at startup or removed/inserted.

Workaround

None.

Fix Information

The sense of the message should change so that it is emitted only when tuning is provided for a module. It also needs to be info level or less.

Behavior Change