Bug ID 587668: LCD Checkmark button does not always bring up clearing prompt on VIPRION blades.

Last Modified: Mar 21, 2019

Bug Tracker

Affected Product:  See more info
BIG-IP TMOS(all modules)

Known Affected Versions:
11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2

Fixed In:
13.0.0, 12.1.1

Opened: Apr 14, 2016
Severity: 3-Major

Symptoms

Pressing the LCD checkmark button does not always bring up clearing prompt on VIPRION blades.

Impact

Cannot clear the alert using the LCD.

Conditions

Pressing the LCD's checkmark button to clear an alert on VIPRION blades.

Workaround

Press the checkmark button followed by the left or right arrow buttons.

Fix Information

In this release, unneeded LCD updates that might have clogged the message channel have been optimized, and the keypress passed along at a later time, so it is not lost. So pressing the LCD checkmark button now correctly brings up clearing prompt on VIPRION blades.

Behavior Change