Bug ID 587892: Multiple iRule proc names might clash, causing the wrong rule to be executed.

Last Modified: Apr 28, 2025

Affected Product(s):
BIG-IP All(all modules)

Known Affected Versions:
11.5.0, 11.5.1, 11.5.1 HF1, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.1 HF10, 11.5.1 HF11, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1

Fixed In:
11.6.1 HF1, 11.5.4 HF3

Opened: Apr 15, 2016

Severity: 3-Major

Related Article: K31010486

Symptoms

Multiple iRule proc names might clash, causing the wrong rule to be executed.

Impact

The call proc might execute the wrong proc.

Conditions

This occurs when there is an iRule configured with more than one proc, which might cause the wrong proc to get executed.

Workaround

None.

Fix Information

Multiple iRules configured with more than one proc no longer cause the wrong proc to get executed.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips