Last Modified: Sep 13, 2023
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.4.1, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2, 12.1.2 HF1, 12.1.2 HF2, 12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6
Fixed In:
13.0.0
Opened: May 11, 2016 Severity: 3-Major
iRule validation does not catch iRule with incorrect 'after' syntax, allowing an invalid iRule to be saved.
Traffic handled by the iRule fails, generating the Tcl error 'invalid command name 'periodic' while executing 'periodic LB::reselect''.
iRule with incorrect 'after' syntax. For example "after 5000 periodic" should be "after 5000 -periodic" (with a hyphen)
Correct the syntax error.
None