Bug ID 597309: Increase the Maximum Members Per Trunk limit to 32 or 64 for high end platforms

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP All(all modules)

Known Affected Versions:
10.2.4, 11.2.1, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1

Fixed In:
13.0.0, 12.1.1 HF2

Opened: Jun 03, 2016

Severity: 3-Major

Symptoms

The Maximum Members Per Trunk limits is 8 or 16 depending on platform. This is due to 1. The limitation of an SDK from a third party vendor. 2. The number of external interfaces actually provided by the platform.

Impact

The number of interfaces per trunk is limited to either 8 or 16.

Conditions

These platform limits are on the BIG-IP 10000 appliance and B2400, B4300, and B4450 blades.

Workaround

None.

Fix Information

New limit of 32 is implemented for the BIG-IP 10000 appliance, and on VIPRION 2400 and VIPRION 4300. New limit 64 is implemented for VIPRION 4450N.

Behavior Change

Guides & references