Bug ID 601309: Locator LED no longer persists across reboots

Last Modified: Nov 07, 2022

Bug Tracker

Affected Product:  See more info
BIG-IP TMOS(all modules)

Known Affected Versions:
12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 13.0.0, 13.0.0 HF1, 13.0.0 HF2, 13.0.0 HF3, 13.0.1

Fixed In:
12.1.1 HF2

Opened: Jun 24, 2016
Severity: 4-Minor

Symptoms

The Locator LED (blinking F5 logo ball) state could be retained across reboots if the TMSH config was saved. The intended behavior is to default to disabled on reboot.

Impact

i5600, i5800, i7600, i7800, i10600, and i10800 appliances

Conditions

Setting the Locator to "enabled" via either the LCD or TMSH, then saving the TMSH config.

Workaround

Disable the Locator LED and save the TMSH config

Fix Information

Fixed Locator LED state persisting through reboots

Behavior Change