Bug ID 601563: LTM Import fails with node configuration with monitor that has port specified

Last Modified: Jul 12, 2023

Affected Product(s):
BIG-IQ ADC(all modules)

Fixed In:
5.1.0

Opened: Jun 27, 2016

Severity: 3-Major

Symptoms

LTM Import fails with following error: Failed to copy configuration to working-config updater: Monitor XXX monitor is not allowed to attach to a node

Impact

Cannot import and manage config until monitor is removed from node

Conditions

Node uses monitor with port specified

Workaround

Remove the port from the monitor.

Fix Information

When a Node uses a monitor with a port specified LTM Import fails with following error: Failed to copy configuration to working-config updater: Monitor XXX monitor is not allowed to attach to a node Now, LTM Import succeeds with monitor having port specification attached to node configuration.

Behavior Change

Guides & references