Last Modified: Nov 07, 2022
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
11.2.1, 11.3.0, 11.4.0, 11.4.1, 11.5.0, 11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.10, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2
Fixed In:
13.0.0, 12.1.3, 11.6.3, 11.5.5
Opened: Jun 27, 2016 Severity: 3-Major Related Article:
K02314881
The I2C internal bus for the front switch on BIG-IP 4340N/4300 blades may not work.
Corrupted serial number information from SFPs, and fiber SFPs may not come up.
This rarely happens.
bigstart restart bcm56xxd
The system now ensures that the I2C internal bus can recover from occasional errors.