Bug ID 603772: Floating tunnels with names more than 15 characters may cause issues during config-sync.

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
12.1.0, 12.1.1, 12.1.2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6

Fixed In:
13.0.0

Opened: Jul 08, 2016

Severity: 3-Major

Symptoms

Floating tunnels with names more than 15 characters may cause issues in config-sync, because such a long name is truncated when creating a corresponding Linux tunnel interface.

Impact

When the config-sync happens, the following error may occur: Caught configuration exception (0), Cannot create tunnel 'g123456789abc~1' in rd0 - ioctl failed: File exists.

Conditions

The BIG-IP system consists of both floating and non-floating tunnels and their names are longer than 15 characters.

Workaround

Some workarounds are available: - Make sure that tunnel names are less than 16 characters; or - Make sure that the names of floating and non-floating tunnels do not share a common prefix in the first 15 characters; or - Make sure that the BIG-IP system does not have a mixture of floating and non-floating tunnels.

Fix Information

None

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips