Last Modified: Nov 07, 2022
Affected Product(s):
BIG-IP LTM
Known Affected Versions:
11.5.1, 11.5.1 HF1, 11.5.1 HF10, 11.5.1 HF11, 11.5.1 HF2, 11.5.1 HF3, 11.5.1 HF4, 11.5.1 HF5, 11.5.1 HF6, 11.5.1 HF7, 11.5.1 HF8, 11.5.1 HF9, 11.5.10, 11.5.2, 11.5.2 HF1, 11.5.3, 11.5.3 HF1, 11.5.3 HF2, 11.5.4, 11.5.4 HF1, 11.5.4 HF2, 11.5.4 HF3, 11.5.4 HF4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.6.0, 11.6.0 HF1, 11.6.0 HF2, 11.6.0 HF3, 11.6.0 HF4, 11.6.0 HF5, 11.6.0 HF6, 11.6.0 HF7, 11.6.0 HF8, 11.6.1, 11.6.1 HF1, 11.6.1 HF2, 11.6.2, 11.6.2 HF1, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.0.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.0, 12.1.0 HF1, 12.1.0 HF2, 12.1.1, 12.1.1 HF1, 12.1.1 HF2, 12.1.2, 12.1.2 HF1, 12.1.2 HF2, 12.1.3, 12.1.3.1, 12.1.3.2, 12.1.3.3, 12.1.3.4, 12.1.3.5, 12.1.3.6, 12.1.3.7, 12.1.4, 12.1.4.1, 12.1.5, 12.1.5.1, 12.1.5.2, 12.1.5.3, 12.1.6
Opened: Jul 15, 2016 Severity: 3-Major Related Article:
K92903310
After creating a monitor using the GUI containing a recv parameter with a backslash such as '\* OK', loading the configuration generates a validation error: 01070753:3: Monitor /Common/test recv parameter contains an invalid regular expression (Invalid preceding regular expression). Unexpected Error: Loading configuration process failed. Attempting to configure the same monitor via tmsh throws the validation error before creating the monitor, but the GUI allows the single backslash. Two backslashes are required in this case.
Configuration fails to load after it is successfully created via the GUI. The GUI accepts this when it should throw a validation error: two backslashes are required.
Using the GUI to configure a monitor, whose receive string needs to look for a backslash, and only a single backslash is entered in the GUI.
When configuring the monitor via the GUI, use two backslashes instead of one.
None