Last Modified: Sep 13, 2023
Affected Product(s):
BIG-IP TMOS
Known Affected Versions:
11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2
Fixed In:
13.0.0, 12.1.2 HF1
Opened: Aug 17, 2016 Severity: 3-Major
vCMP: VLAN failsafe does not trigger on guest due to IPv6 link-local neighbor discovery traffic from host.
Since the heartbeat messages going over IPv6 link-local addresses continue to be successfully passed from host to guest, VLAN failsafe does not trigger if a downstream router or switch goes down that's connected to the VLAN.
vCMP host configured, VLAN failsafe enabled on a VLAN, one or more VCMP guests enabled that use that VLAN
If you are able to, disabling IPv6 on the host will allow VLAN failsafe to work as expected.
None