Bug ID 621909: Uneven egress trunk distribution on 5000/10000 platforms with odd number of trunk members

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP LTM(all modules)

Known Affected Versions:
11.5.1, 11.5.2, 11.5.3, 11.5.4, 11.5.5, 11.5.6, 11.5.7, 11.5.8, 11.5.9, 11.5.10, 11.6.0, 11.6.1, 11.6.2, 11.6.3, 11.6.3.1, 11.6.3.2, 11.6.3.3, 11.6.3.4, 11.6.4, 11.6.5, 11.6.5.1, 11.6.5.2, 11.6.5.3, 12.0.0, 12.0.0 HF1, 12.1.0 HF1, 12.0.0 HF2, 12.1.0 HF2, 12.0.0 HF3, 12.0.0 HF4, 12.1.1 HF1, 12.1.1 HF2

Fixed In:
13.0.0, 12.1.2 HF1

Opened: Oct 11, 2016

Severity: 3-Major

Related Article: K23562314

Symptoms

When a trunk on the BIG-IP 5000 or 10000 platforms has an odd number of members, the traffic distribution to those interfaces will be unbalanced. Some interfaces will see more traffic than others.

Impact

Uneven traffic distribution.

Conditions

This can occur for two reasons: -- Purposefully configuring an odd number of members. -- A port goes down in a trunk that has an even number of members.

Workaround

None.

Fix Information

This release fixes uneven egress trunk distribution on the BIG-IP 5000 or 10000 platforms when there is an odd number of ports.

Behavior Change

Guides & references