Bug ID 628009: f5optics not enabled on Herculon iSeries variants HRC-i2800, HRC-i5800, HRC-i10800

Last Modified: Sep 13, 2023

Affected Product(s):
BIG-IP TMOS(all modules)

Fixed In:
12.1.2 HF1

Opened: Nov 10, 2016

Severity: 3-Major

Symptoms

The f5optics functionality is not initialized on Herculon iSeries variants.

Impact

None. No f5optics optics module database is presently provided for Herculon platforms. Herculon uses no optics modules that require tuning (e.g., 100G).

Conditions

This occurs on the following Herculon iSeries platforms: HRC-i2800, HRC-i5800, HRC-i10800.

Workaround

None.

Fix Information

With the fix, if an optics module data base is provided via an f5optics install, f5optics will become operational on Herculon. An f5optics database will be provided if optics modules requiring tuning are ever used with Herculon.

Behavior Change

Guides & references

K10134038: F5 Bug Tracker Filter Names and Tips